Pharmaceutical water systems
Clean water,clear results.
We design, install and validate Purified Water and Water for Injection systems for pharmaceutical, food and biotech manufacturers — built to cGMP, USP, ASME BPE and EHEDG.
At a glance
SS316L
Sanitary material standard across every loop we build
< 0.38 µm
Electropolished surface roughness available on Rensa fittings
0.5" – 6"
Pipe and fitting sizes supplied as authorized Rensa agent
500 L – 20 t
Sanitary tank and vessel capacity range
What we deliver
End-to-endwater systems
One team from specification through qualification. No handoffs between a supplier, a contractor and a validation consultant who have never met.
- 01
Purified Water (PW) generation
High-quality Purified Water generation customised for pharmaceutical manufacturing.
Learn more - 02
Water for Injection (WFI) generation
WFI generation systems built to the standards that govern injectable manufacturing.
Learn more - 03
Storage and distribution loops
PW and WFI loops designed and installed to GMP, using high-quality orbital welding.
Learn more - 04
Orbital welding and installation
Automated, documented welding for pharmaceutical, biotech, food and semiconductor manufacturing.
Learn more
Supply
Sanitary equipmentand instrumentation

Pipes and fittings
SS316L sanitary pipes and fittings in mechanical-polish and electropolish finishes, supplied as the authorized Rensa agent in Egypt.
View details
Hygienic pumps
Centrifugal pumps that meet GMP and FDA standards, specified for PW and WFI distribution loops.
View details
Sanitary valves
Manual and pneumatic SS316L valves adhering to ASME BPE, DIN, ASTM and 3-A standards.
View details
Tanks and vessels
Sanitary stainless steel tanks and vessels from 500 litres to 20 tons, single-wall through pressurised.
View details
Instrumentation
Sanitary level, flow, temperature, pressure, conductivity, pH and ORP instruments for pharmaceutical process lines.
View details
Authorized agent
Rensa sanitary pipes and fittings in Egypt
As the authorized Rensa agent, we supply SS316L sanitary pipes and fittings with mechanical-polish (Ra < 0.5 µm) and electropolish (Ra < 0.38 µm) finishes, in sizes from 0.5 to 6 inches.
Compliance by default
Every project,to standard.
Standards are not a checklist attached at the end of a project. They are decisions made at the start — material grade, surface finish, loop velocity, weld documentation.
Standards- cGMP
- USP
- FDA
- ISPE
- ASME BPE
- DIN
- ASTM
- 3-A
- EHEDG
Planning a PW or WFI system?